DC TO AC SOLID STATE RELAY
SALIENT FEATURES
- True Zero Cross Over
- Virtually Free from EMI/RFI
- Input Green LED Indication
- Output to body 4kV Isolation
- Output N/O configuration
- Noiseless without Chattering and Fast Switching
- Inbuilt Snubber
- Heatsink + Dinrail Mounting (35mm)
- Reverse polarity protection.
- Random type SSR (optionally)
|
MODEL |
Input |
Output |
NO. |
Type of SSR |
Voltage |
Current |
Voltage |
Current Amp at 20ºC |
Current Amp With HeatSink 55ºC |
Fusing Current I²T |
1 |
SSR-SS4-DA-4810 |
4-32VDC |
4-16mA |
480VAC |
10Amp |
07Amp |
300A²S |
2 |
SSR-SS4-DA-4816 |
4-32VDC |
4-16mA |
480VAC |
16Amp |
10Amp |
300 A²S |
3 |
SSR-SS4- DA 48 25 |
4-32VDC |
4-16mA |
480VAC |
25Amp |
18Amp |
500A²S |
4 |
SSR-SS4- DA 48 50 |
4-32VDC |
4-16mA |
480VAC |
50Amp |
35Amp |
3000A²S |
5 |
SSR-SS4-DA 48 75 |
4-32VDC |
4-16mA |
480VAC |
75Amp |
45Amp |
6000 A²S |
6 |
SSR-SS4- DA 48 90 |
4-32VDC |
4-16mA |
480VAC |
90Amp |
55Amp |
7200A²S |
7 |
SSR-SS4- DA 48 110 |
4-32VDC |
4-16mA |
480VAC |
110Amp |
65AMP |
10000A²S |
8 |
SSR-SS4- DA 48 150 |
4-32VDC |
4-16mA |
480VAC |
150Amp |
85AMP |
15000A²S |
9 |
SSR-SS4- DA 48 175 |
4-32VDC |
4-16mA |
480VAC |
175Amp |
90AMP |
20000A²S |
10 |
SSR-SS4- DA 48 200 |
4-32VDC |
4-16mA |
480VAC |
200Amp |
100AMP |
25000A²S |
Input Technical Data |
Input Control Supply Voltage |
80-280VAC |
Input Control Supply Current |
4-16mA |
Output Technical Data |
Operational Voltage Range |
Vrms |
24-480VAC |
Peak Inverse Voltage |
Vpk |
1200Vpk |
Rated operational Current at 20ºC |
IT |
25/50/90Amp AC |
Rated operational Current at 55ºC |
IT |
18/35/55Amp AC |
Max. OFF State Leackage Current |
mA |
< 2 mArms |
Minimum Holding Current |
IH |
175/275/275mA |
Rated Peak WithStand Current |
ITSM |
320/775/1200A |
Max. Load Integral i²dt (t=10ms) |
I²t |
500/3000/7200A²S |
Voltage Drop in ON-State |
VTM |
1.3V |
Isolation Voltage |
KVA |
4KVA |
Advantages |
Contac Less Logic Relay with Switching Performed by Semiconductor Device |
True Zero Voltage turn ON/OFF |
Input Output Isolation 4000VA |
High Speed and High Frequency Switching |
Longer Life Dus to Infinite Number of Switching |
Precaution |
For Load Current More Than 3Amp External Heatsink is Must |
Apply Heatsink Pest on the Base Plate of the Before Mounting it External Heatsink |
Fast Acting Fuse Require For Protection SSR |
SSR Rating Should Be More or Equal to Maximum Jerk Current of Load |
Do not check SSR Meter or Continuity Tester Otherwise.It will Always Shows OPEN |
Application |
Temp.Controller in Ovens & Furnaces |
Plastic Processing, Injection Moulding, Blow Moulding & Extrusion Machineries |
Forward-Reverse of Motor in CNC Machines |
Printing Machinery |
Texturising Machinery |
Medical Equipments |
ON/OFF Motors.Control |
Hot Runner Systems |
Controlling of Infrared Heaters |
Solid and Liquid Packaging Equipments |
Refrigeration System and Appliances |
- INPUT: -3-32 VDC
- OUTPUT: -240/330/440 VAC
- MODEL NO: -101/111/119/122
NOTES: ZERO CROSS OVER/RANDOM/CMOS Body isolation: 4kV for 1 min I/p.to O/P isolation : More than 6kV for 1 min.