PHASE ANGLE CONTROLLER SSR


SALIENT FEATURES

  • OPTO Isolation 4000Vrms
  • The Load Power is Proportional to Controller Analog Input
  • Linearity Better than 2% of the Rang
  • Output to body 4kV Isolation
  • Inbuilt Snubber
  • Heatsink + Dinrail Mounting (35mm)
MODEL Input Output
NO. Type of SSR Voltage/Current Voltage Current Amp at 20ºC Current Amp With HeatSink 55ºC Fusing Current I²T
1 01 PHT 24 25 420 4-20mA/0-10VDC 230VAC 25Amp 12Amp 500A²S
2 01 PHT 24 50 420 4-20mA/0-10VDC 230VAC 50Amp 22Amp 3000A²S
3 01 PHT 24 90 420 4-20mA/0-10VDC 230VAC 90Amp 42Amp 7200A²S
4 01 PHT 44 25 420 4-20mA/0-10VDC 440VAC 25Amp 12Amp 500A²S
5 01 PHT 44 50 420 4-20mA/0-10VDC 440VAC 50Amp 22Amp 3000A²S
6 01 PHT 44 90 420 4-20mA/0-10VDC 440VAC 90Amp 42Amp 7200A²S

Input Technical Data
Input Signal Voltage VDC 0-10VD
Input Impedance Ohm 560
Input Signal Current mA 4-20mA
Input Impedance Ohm 100


Output Technical Data
Operational Voltage Range Vrms 0-230VAC or 0-440VAC
Peak Inverse Voltage Vpk 1200Vpk
Rated operational Current at 20ºC IT 25/50/90Amp AC
Rated operational Current at 55ºC IT 18/35/55Amp AC
Max. OFF State Leackage Current mA < 2 mArms
Minimum Holding Current IH 175/275/275mA
Rated Peak WithStand Current ITSM 320/775/1200A
Max. Load Integral i²dt (t=10ms) I²t 500/3000/7200A²S
Voltage Drop in ON-State VTM 3 to 4V
Isolation Voltage KVA 4KVA


Application
Polyester Yarn Processing Industry
Paper Industry
Furnace Industry
Ceramic Industry
Electroplating Machinery
Glass Industry
Biscuit Making Machinery


Precaution
Used for Resistive Load only
SSR will not work if Heater is Connected in Star without Neutral
Do not give DC Voltage at 4-20mA Input Control of SSR otherwise Input of SSR will Fail